KM02-01
This series of products adopt photoelectric direct reading module to read the water consumption data and upload it through a special wire. The whole system consists of water meter, collector and management center. Direct reading function, no built-in battery, long service life, waterproof, anti-static, moisture-proof, anti-dust, anti-magnetic interference, optional control valve, high waterproof level.
Description
1. Features
● Multi-jet vane wheel, separate sealing structure, easy to replace and maintain.
● Dry type register, magnetic drive, long-term clear reading.
● Material: iron, plastic, brass, stainless.
● Moisture-proof, sun-proof, anti-fluctuation,anti-static, anti-magnetic interference,anti-freezing, IP68.
● Water consumption can be read or recorded real-time.
● Environment: B, E1.
● Zero power supply except reading water consumption.
● Easy to add and maintain water meters and collectors.
2. Electronic Technique
|
Working Voltage |
Working Temperature |
Working Current |
Output |
|
DC9-15V(RS-485) |
-10~45 ℃ |
≤9mA |
RS-485 |
3. Head Loss Curve 
4. Accuracy Error Curve
5. Installation Dimension 
|
Item No |
LXSGY-15 |
LXSGY-20 |
LXSGY-25 |
LXSGY-32 |
LXSGY-40 |
|
|
L1 |
mm |
258 |
305 |
345 |
354 |
373 |
|
L |
mm |
165 |
195 |
225 |
230 |
245 |
|
H |
mm |
110 |
110 |
115 |
115 |
155 |
|
W |
mm |
95 |
95 |
110 |
110 |
125 |
|
Connection Thread |
D(mm) |
G3/4" |
G1" |
G1 1/4" |
G1 1/2" |
G2" |
|
d(mm) |
R1/2 |
R3/4 |
R1 |
R1 1/4 |
R1 1/2 |
|
|
Weight |
with unions(kg) |
|
|
|
|
|
|
without unions(kg) |
1 |
1.2 |
1.7 |
2.2 |
|
|
6. Main Technical Parameter
|
Model number |
LXSGY-15 |
LXSGY-20 |
LXSGY-25 |
LXSGY-32 |
LXSGY-40 |
||||||||||
|
Nominal diameter (DN)[mm] |
15 |
20 |
25 |
32 |
40 |
||||||||||
|
Ratio Q3/Q1 |
R80 |
R100 |
R160 |
R80 |
R100 |
R160 |
R80 |
R100 |
R160 |
R80 |
R100 |
R160 |
R80 |
R100 |
R160 |
|
Overload flow rate (Q4) [m³/h] |
3.125 |
3.125 |
3.125 |
5 |
5 |
5 |
7.875 |
7.875 |
7.875 |
12.5 |
12.5 |
12.5 |
20 |
20 |
20 |
|
Permanent flow rate (Q3) [m³/h] |
2.5 |
2.5 |
2.5 |
4 |
4 |
4 |
6.3 |
6.3 |
6.3 |
10 |
10 |
10 |
16 |
16 |
16 |
|
Transitional flow rate (Q2) [m³/h] |
0.05 |
0.04 |
0.025 |
0.08 |
0.064 |
0.04 |
0.126 |
0.1 |
0.063 |
0.2 |
0.16 |
0.1 |
0.32 |
0.256 |
0.16 |
|
Minimum flow rate (Q1) [m³/h] |
0.032 |
0.025 |
0.015 |
0.05 |
0.04 |
0.025 |
0.08 |
0.063 |
0.039375 |
0.125 |
0.1 |
0.0625 |
0.2 |
0.16 |
0.1 |
|
Accuracy class |
2 |
||||||||||||||
|
Maximum permissible error for the lower flow rate zone (MPEι) |
±5% |
||||||||||||||
|
Maximum permissible error for the upper flow rate zone (MPEμ) |
±2% for water having a temperature ≤30℃ |
||||||||||||||
|
Temperature class |
T30,T50 |
||||||||||||||
|
Water pressure classes |
MAP 16 |
||||||||||||||
|
Pressure-loss classes |
△P63 |
||||||||||||||
|
Indicating range[m³] |
99 999 |
||||||||||||||
|
Resolution of the indicating device[m³] |
0.00005 |
||||||||||||||
|
Flow profile sensitivity classes |
U10 D5 |
||||||||||||||
|
Orientation limitation |
HORIZONTAL |
||||||||||||||
In today's increasingly refined water resource management, prepaid water meter technology is becoming a key tool for utilities worldwide to improve ma...
In modern urban water management and industrial fluid metering, the measurement accuracy and long-term stability of water meters are core elements for...
In the design and management of modern commercial real estate, residential apartments, and various industrial parks, water fee collection and excess l...
In the field of industrial water management and precision liquid measurement, selecting the appropriate water flow meter is a critical decision that i...